top of page

Heat and sound insulation of facades

5-1.jpg

"FACADE" series

 

The facade is the "face" of the building, which has a great aesthetic value, its architectural appearance. But, in addition to this, an integral part in the construction of new objects and in the reconstruction of old ones is the insulation of the external walls of buildings.

In different facade structures, different heat and sound insulation materials should be used, the choice of which is determined by the characteristics and the amount of operational loads on the heat and sound insulation layer in each specific system.

The most common types of facade heat and sound insulation structures:

 

  • facade systems with finishing with light or heavy plaster;

  • facade systems with a ventilated air layer.


Facade heat and sound insulation NOVOTERM provides:

  • savings on heating and air conditioning of the building;

  • improvement of microclimate parameters of indoor spaces;

  • high level of sound insulation;

  • lack of possibility of appearance of mold on external walls;

  • increasing the durability of load-bearing structures.

__.jpg

NOVOTERM

"Facade 100"

*The recommended height of the facade system is no more than 10 m.

"Facade 110"
"Facade 115"
"Facade 120"

*Private housing construction

"Facade 125"
"Facade 130"
"Facade 135"
"Facade 145"

They are used as a heat and sound insulation layer in facade systems with a thin plaster layer.

5-1.jpg

"PRO" series

 

TM NOVOTERM expanded the line of facade thermal and sound insulation and introduced additional products with an increased strength index for multi-story buildings and private residential construction.

NT FasPRO 15

It is used as a heat-sound insulation layer in facade systems with a thin plaster layer;

NT FasPRO 12

It is used as a heat and sound insulation layer in

facade systems with a thin plaster layer

(private residential construction).

PHYSICAL AND MECHANICAL INDICATORS

The version of physical and technical indicators in English is available for download

Показник
НТ Фасад 100
Щільність, кг/м3 ± 10%
100
Стабільність розмірів по довжині, ширині, товщині при [(25 ± 2) °С, (90 ± 5)%, 48 г], %, не більше
1
Теплопровідність при температурі (10 ± 0,5) °С, Вт/(м·К), не більше
0,034
Теплопровідність при температурі (25 ± 5) °С, Вт/(м·К), не більше
0,037
Міцність на стиск при 10% деформації, кПа, не менше
25
Стисливість, %, не більше
-
Границя міцності при розтягуванні в напрямку, перпендикулярному площині плити, кПа, не менше
10
Вміст органічних речовин, % за масою, не більше
4,5
Водопоглинання при повному зануренні, % за об'ємом, не більше
1,5
Водопоглинання при частковому зануренні короткочасне, кг/м2, не більше
1
Водопоглинання при частковому зануренні довгострокове, кг/м2 , не більше
3
Паропроникність, м2 /м·год·Па, не менше
0,3
Повітропроникність, кг/м2 ·год, не більше
0,3
Вологість, % за масою, не більше
1
Термін ефективної експлуатації, років, не менше
50